ABB SPAU 130 C Three-Phase Overvoltage and Undervoltage Relay
ABB SPAU 130 C Three-Phase Overvoltage and Undervoltage Relay Supplier and Exporter in India
ABB SPAU 130 C Replacement – REX615 Retrofit
ABB SPAU 130 C is a legacy SPACOM voltage protection relay. ABB lists the product as not active since 2009, so current enquiries are mainly for existing relay replacement, matching spares, plant shutdown requirements and retrofit of older protection panels.
ABB officially includes SPAU 130 C in its SPACOM-to-REX615 Relay Retrofit Program. The program uses a REX615 relay with a retrofit connector kit and is intended to reduce major rewiring when an old SPACOM relay is replaced.
ABB has also documented SPAU 130 C in its SPACOM-to-REX610 retrofit program, so the final replacement should be selected according to the existing relay, required functions and retrofit scope rather than simply choosing a newer relay by model name.
For an ABB SPAU 130 C replacement or retrofit enquiry, please send:
- Complete SPAU 130 C order code
- Clear photograph of the existing relay nameplate
- Rated voltage – 100 V or 110 V
- Auxiliary supply voltage
- Existing protection settings, if available
- Required quantity
- Destination country
ARP IMPEX handles requirements for ABB SPAU 130 C replacement relays, legacy SPACOM spares and SPAU 130 C retrofit projects from India.
Description
ARP IMPEX supplies and exports ABB SPAU 130 C three-phase overvoltage and undervoltage relays for existing switchgear, substations, industrial plants and maintenance requirements.
SPAU 130 C is an older ABB SPACOM voltage relay used for overvoltage and undervoltage protection and supervision in electrical distribution systems. It normally measures all three phase-to-phase voltages, giving it wider voltage supervision than SPAU 121 C. The relay can also be configured for single-phase measurement where required.
Apart from distribution substations, ABB lists SPAU 130 C for voltage protection of generators, motors and transformers. This makes the model relevant to buyers maintaining older MV panels, generator protection panels and industrial substations.
The relay provides separate overvoltage and undervoltage functions. The overvoltage stage can operate with definite-time or inverse-time characteristics, while the undervoltage stage uses definite-time operation.
If you are looking for an ABB SPAU 130 C supplier in India, SPAU 130 C price, SPAU 130 C replacement relay, discontinued ABB voltage relay or SPAU 130 C retrofit, send the complete part code or existing nameplate for checking.
Request a Quote for ABB SPAU 130 C
For pricing and availability, please share:
- Complete ABB SPAU 130 C order code
- Clear relay nameplate photograph
- Required quantity
- Destination country
- Required delivery schedule
When the complete order code is unavailable, please mention:
- 100 V or 110 V voltage input
- 50 Hz or 60 Hz
- Auxiliary supply voltage
- Existing SPAU 130 C or retrofit requirement
For a matching legacy spare, the existing relay nameplate is normally the best starting point.
Why Buy ABB SPAU 130 C from ARP IMPEX?
- Support for legacy ABB SPACOM relay requirements
- Part-code and nameplate checking
- Matching spare and replacement enquiries
- Quotations for single units and multiple quantities
- Support for discontinued ABB relay requirements
- Assistance with REX615 retrofit enquiries
- Support for REX610 retrofit requirements where applicable
- Technical datasheets with quotation
- Export packing and international shipping assistance
- Supply support for utilities, EPC contractors and industrial maintenance buyers
ABB SPAU 130 C Model and Product Status
SPAU 130 C is a specific ABB relay model, not a product family containing several separate model numbers.
It belongs to ABB’s SPACOM / SPAU voltage protection range and uses the SPCU 3C14 three-phase overvoltage and undervoltage relay module.
- Model: SPAU 130 C
- Series: SPACOM / SPAU
- Product type: Three-phase overvoltage and undervoltage relay
- Product status: Not active since 2009
- Main application: Voltage protection and supervision
- Protected equipment: Distribution systems, generators, motors and transformers
Most SPAU 130 C requirements today are related to existing installations rather than new protection projects.
Technical Specifications
- Brand: ABB
- Series: SPACOM / SPAU
- Model: SPAU 130 C
- Product type: Three-phase overvoltage and undervoltage relay
- Product status: Legacy / not active since 2009
- Overvoltage protection: U>
- Undervoltage protection: U<
- ANSI protection functions: 59 and 27
- Voltage measurement: Three-phase-to-phase voltages
- Single-phase measurement: Configurable
- Rated voltage inputs: 100 V or 110 V
- Rated frequency: 50 Hz or 60 Hz depending on ordered version
- Overvoltage characteristic: Definite time or inverse time
- Undervoltage characteristic: Definite time
- External undervoltage blocking: Available
- Trip outputs: Two trip outputs
- Start/signalling outputs: Available
- Relay module: SPCU 3C14
- Serial communication: SPA interface
- Fibre-optic bus communication: Available through applicable SPA-ZC module
- Auxiliary supply: Different AC/DC versions depending on order code
- Digital indication: Measured, setting and recorded values
- Self-supervision: Continuous internal relay supervision
- Mounting: Panel-mounted SPACOM construction
The exact voltage input, auxiliary supply, frequency and terminal arrangement should be confirmed from the complete SPAU 130 C order code or existing relay nameplate.
Features
- Three-phase voltage supervision
- Overvoltage protection
- Undervoltage protection
- Three-phase-to-phase voltage inputs
- Optional single-phase measurement
- Definite-time overvoltage operation
- Inverse-time overvoltage operation
- Definite-time undervoltage operation
- External blocking of undervoltage protection
- Automatic undervoltage blocking
- Separate trip outputs
- Start and alarm signalling
- Voltage measurement
- Recorded fault information
- Digital front display
- SPA serial communication
- Fibre-optic substation bus connection through applicable module
- Continuous hardware and software self-supervision
- 100 V and 110 V voltage inputs
- 50 Hz and 60 Hz versions
SPAU 130 C is mainly a voltage protection relay, so buyers normally need to confirm the existing voltage input, auxiliary supply and protection settings rather than work through a long list of multifunction relay options.
Applications
ABB SPAU 130 C is commonly found in:
- Distribution substation voltage protection
- Three-phase overvoltage protection
- Three-phase undervoltage protection
- Busbar voltage supervision
- Generator voltage protection
- Motor voltage protection
- Transformer voltage protection
- Incoming feeder voltage supervision
- Medium-voltage switchgear
- Industrial substations
- Power distribution panels
- Generator protection panels
- Existing ABB SPACOM installations
- Legacy switchgear maintenance
- Plant shutdown spare requirements
- Existing SPAU 130 C replacement
- Protection-panel retrofit projects
ABB specifically lists distribution substations, generators, motors and transformers as SPAU 130 C applications.
Industries Using ABB SPAU 130 C
Existing SPAU 130 C relays may be found in:
- Power utilities
- Power plants
- Captive power plants
- Steel plants
- Cement plants
- Mining operations
- Oil and gas facilities
- Refineries
- Petrochemical plants
- Manufacturing facilities
- Water-treatment plants
- Industrial substations
For these buyers, SPAU 130 C enquiries are often related to an existing panel where keeping the same relay or moving to a supported retrofit solution is the main requirement.
ABB SPAU 130 C Replacement
Because SPAU 130 C has been inactive since 2009, replacement is one of the main commercial requirements for this model.
Buyers may require:
- Original SPAU 130 C spare
- Matching legacy relay
- Replacement for a failed relay
- Plant shutdown spare
- Spare for existing switchgear
- Modern retrofit for an old SPACOM installation
For an ABB SPAU 130 C replacement relay, send:
- Complete ABB order code
- Clear nameplate photograph
- Required quantity
- Destination country
For an exact legacy replacement, confirm:
- 100 V or 110 V input
- 50 Hz or 60 Hz
- Auxiliary supply
- Existing trip and alarm arrangement
ABB SPAU 130 C Replacement with REX615
ABB currently includes SPAU 130 C in its official SPACOM-to-REX615 retrofit program.
The program includes:
- ABB REX615 protection and control relay
- Retrofit connector kit
- Documentation
- Configuration support options
- Installation accessories and support where required
ABB states that the retrofit arrangement is intended to minimise major new wiring and reduce shutdown time when replacing supported SPACOM relays.
A SPAU 130 C to REX615 retrofit may be considered when:
- The original SPAU 130 C is difficult to source
- An existing relay has failed
- Long-term relay support is required
- Old switchgear is being modernised
- Additional protection or monitoring is required
- IEC 61850 communication is being introduced
Before finalising the retrofit, check:
- Existing three-phase voltage inputs
- 100 V / 110 V selection
- Auxiliary supply
- Trip contacts
- Alarm contacts
- Undervoltage blocking
- Protection settings
- Existing panel wiring
ABB SPAU 130 C Replacement with REX610
ABB also documents an official SPACOM-to-REX610 retrofit program that includes SPAU 130 C. ABB identifies the replacement REX610 order-code structure as REX6101G#B###### for this legacy relay.
The REX610 retrofit program includes:
- REX610 replacement relay
- Retrofit adapter set
- Documentation
- Optional configuration template
- Installation and testing support tools
For a buyer, this means there can be more than one ABB-supported modernisation route for SPAU 130 C. The correct choice between REX610 and REX615 should be made from the actual existing panel, required functions, communication needs and future protection requirements.
Information Required for ABB SPAU 130 C Quotation
For most enquiries, please send:
- Complete ABB SPAU 130 C order code
- Clear relay nameplate photograph
- Required quantity
- Destination country
- Required delivery schedule
If the complete code is unavailable:
- 100 V or 110 V voltage input
- 50 Hz or 60 Hz frequency
- Auxiliary supply voltage
- Original SPAU 130 C, REX610 retrofit or REX615 retrofit requirement
ARP IMPEX accepts enquiries against an ABB part number, relay nameplate, BOQ or existing protection-panel information.
Contact us for ABB SPAU 130 C price, SPAU 130 C replacement relay, discontinued ABB SPAU 130 C availability, ABB three-phase voltage relay supplier in India, legacy SPACOM spare, REX610 replacement or SPAU 130 C to REX615 retrofit quotation from India.
Related products
-

Legrand RTX3 40 Thermal Overload Relay 0.1 to 0.16 A (For CTX3 22 and 40) 416640
-

Legrand RTX3 40 Thermal Overload Relay 4 to 6 A (For CTX3 22 and 40) 416648
-

Legrand RTX3 40 Thermal Overload Relay 0.1 to 0.16 A (For CTX3 22 and 40) 416660
-

Legrand RTX3 40 Thermal Overload Relay 0.25 to 0.4 A (For CTX3 22 and 40) 416642