ABB SPAU 110 C Residual Overvoltage Relay
ABB SPAU 110 C Residual Overvoltage Relay Supplier and Exporter in India
ARP IMPEX handles enquiries for ABB SPAU 110 C residual overvoltage relays for existing switchgear, substations, industrial plants and replacement requirements.
ABB SPAU 110 C is an older SPACOM voltage protection relay used mainly for earth-fault protection and residual voltage supervision. It is found in isolated-neutral, resistance-earthed and reactance-earthed electrical networks. The relay has also been used for generator and motor earth-fault protection and for capacitor bank unbalance protection.
SPAU 110 C provides two residual overvoltage stages. Depending on the protection scheme, one stage can be used for alarm or supervision and the second for tripping.
ABB has listed SPAU 110 C as a non-active product since 2009, so most requirements today are for a matching spare, replacement of an installed relay or modernisation of an existing protection panel.
If you are looking for an ABB SPAU 110 C supplier in India, SPAU 110 C price, discontinued ABB SPAU relay, SPAU 110 C replacement or REX615 retrofit, send us the existing relay nameplate and required quantity for checking.
Request a Quote for ABB SPAU 110 C
For pricing and availability, please send:
- Complete ABB SPAU 110 C order code
- Clear photograph of the existing relay nameplate
- Required quantity
- Destination country
- Required delivery schedule
If the complete order code is unavailable, please mention:
- Rated residual voltage – 100 V or 110 V
- Auxiliary supply voltage
- Existing SPAU 110 C or REX615 retrofit requirement
For an old relay replacement, the nameplate is normally the best starting point.
Why Buy ABB SPAU 110 C from ARP IMPEX?
- Support for legacy ABB SPACOM relay enquiries
- Part-code and nameplate checking before quotation
- Matching spare and replacement requirements
- Quotations for single units and multiple quantities
- Support for discontinued ABB relay requirements
- Assistance with SPAU 110 C to REX615 retrofit enquiries
- Technical datasheets with quotation
- Export packing and international shipping assistance
- Supply support for utilities, EPC contractors and industrial maintenance buyers
ABB SPAU 110 C Model and Product Status
SPAU 110 C is a specific ABB relay model, not a family containing several individual relay models.
It belongs to ABB’s older SPACOM / SPAU voltage relay range and uses the SPCU 1C6 residual voltage relay module.
ABB currently classifies SPAU 110 C as a legacy product and states that it has not been active since 2009.
Because of this, buyers normally search for SPAU 110 C for:
- Existing relay replacement
- Maintenance spare
- Plant shutdown requirement
- Matching relay for old switchgear
- Legacy ABB SPACOM stock
- Upgrade to a current ABB relay
Technical Specifications
- Brand: ABB
- Series: SPACOM / SPAU
- Model: SPAU 110 C
- Product type: Residual overvoltage relay
- Product status: Legacy / not active since 2009
- Main protection: Residual overvoltage / earth-fault supervision
- Protection function: ANSI 59N
- Protection stages: 2 independent residual overvoltage stages
- Low-set stage: U0>
- High-set stage: U0>>
- Low-set setting range: Approximately 2–20% × Un
- High-set setting range: Approximately 10–80% × Un
- Operating characteristic: Definite time
- Rated residual voltage: 100 V or 110 V
- External blocking input: Available
- Trip outputs: Available
- Alarm/signalling outputs: Available
- Serial communication: SPA serial interface
- Fibre-optic communication: Available through applicable SPA-ZC bus module
- Wide auxiliary supply: 80–265 V AC/DC
- Low-voltage DC supply: 18–80 V DC
- Digital indication: Setting values, measured residual voltage and recorded fault values
- Self-supervision: Built-in continuous relay supervision
- Mounting: Panel-mounted SPACOM construction
The rated voltage and auxiliary supply should always be confirmed from the complete SPAU 110 C order code or existing nameplate.
Features
- Residual overvoltage protection
- Earth-fault supervision
- Two independent protection stages
- Low-set residual overvoltage stage
- High-set residual overvoltage stage
- Separate alarm and trip use
- Definite-time operation
- External blocking input
- Flexible trip and signalling outputs
- Residual voltage measurement
- Fault-value recording
- Digital display
- SPA serial communication
- Fibre-optic substation bus connection through applicable module
- Built-in relay self-supervision
- 100 V and 110 V residual-voltage inputs
- Different auxiliary supply versions
ABB specifically lists residual overvoltage protection, two independent operation stages, selectable output functions, serial communication and continuous self-supervision among the SPAU 110 C features.
Applications
ABB SPAU 110 C is commonly found in:
- Earth-fault protection systems
- Residual voltage supervision
- Isolated-neutral networks
- Resistance-earthed networks
- Reactance-earthed networks
- Resonant-earthed networks
- Distribution substations
- Generator earth-fault protection
- Motor earth-fault protection
- Capacitor bank unbalance protection
- Busbar residual voltage supervision
- Existing medium-voltage switchgear
- Utility substations
- Industrial electrical distribution systems
- Legacy ABB SPACOM protection panels
- Existing SPAU 110 C replacement requirements
ABB also documents SPAU 110 C for generator and motor earth-fault protection and capacitor-bank unbalance applications.
ABB SPAU 110 C for Capacitor Bank Protection
SPAU 110 C can be used for unbalance protection of star-connected capacitor banks.
A change in capacitor bank balance produces residual voltage. SPAU 110 C can monitor this voltage, with one stage used for alarm and another for trip according to the protection requirement.
This makes old SPAU 110 C units relevant for buyers maintaining:
- Capacitor bank panels
- Reactive power compensation systems
- Utility capacitor banks
- Industrial MV capacitor banks
ABB SPAU 110 C Replacement
Replacement is one of the main reasons buyers now search for SPAU 110 C.
Since ABB stopped active supply of the product in 2009, an existing installation may require:
- Original SPAU 110 C spare
- Matching legacy relay
- Replacement after relay failure
- Shutdown spare
- Modernisation of the complete protection panel
For an ABB SPAU 110 C replacement relay, please send:
- Complete order code
- Relay nameplate photograph
- Rated residual voltage
- Auxiliary supply
- Required quantity
- Destination country
Do not select an old SPAU relay only from the model number when an exact replacement is required.
ABB SPAU 110 C to REX615 Retrofit
ABB officially includes SPAU 110 C in its Relay Retrofit Program for SPACOM to REX615.
ABB’s retrofit program uses a REX615 protection and control relay together with a retrofit connector kit to help replace the old SPACOM relay while reducing rewiring work. The replacement still requires application-specific configuration and settings.
ABB lists the following retrofit order-code structures specifically for SPAU 110 C:
- RRPSPAU110CREX615C – REX615 supplied with pre-configuration
- RRPSPAU110CREX615N – REX615 supplied without pre-configuration
A SPAU 110 C to REX615 retrofit should be checked against the existing:
- Residual voltage input
- Auxiliary supply
- Trip outputs
- Alarm contacts
- Blocking signal
- Existing protection settings
- Panel cut-out and wiring
For an ABB SPAU 110 C to REX615 retrofit enquiry, send the existing relay nameplate and available settings.
Contact us for ABB SPAU 110 C price, SPAU 110 C replacement relay, discontinued ABB SPAU 110 C availability, ABB residual overvoltage relay supplier in India, legacy SPACOM spare or SPAU 110 C to REX615 retrofit quotation from India.
Related products
-

Legrand RTX3 40 Thermal Overload Relay 0.63 to 1 A (For CTX3 22 and 40) 416664
-

Legrand RTX3 40 Thermal Overload Relay 0.25 to 0.4 A (For CTX3 22 and 40) 416642
-

Legrand RTX3 40 Thermal Overload Relay 9 to 13 A (For CTX3 22 and 40) 416652
-

Legrand RTX3 40 Thermal Overload Relay 0.25 to 0.4 A (For CTX3 22 and 40) 416662